3Com 4500 50-PORT Switch User Manual


 
342 CHAPTER 12: USING SYSTEM MANAGEMENT COMMANDS
Parameter
unit unit-id: Specify the Unit ID of the switch
power-ID: Power ID.
Description
Use the display power command to display the working state of the built-in
power supply.
Example
Show power state.
<SW4500>display power 1
Unit1
power 1 State: Normal
display schedule reboot Syntax
display schedule reboot
View
Any view
Parameter
None
Description
Use the display schedule reboot command to check the configuration of
related parameters of the switch schedule reboot terminal service.
Related command: reboot, schedule reboot at, schedule reboot delay,
undo schedule reboot.
Example
Display the configuration of the schedule reboot terminal service parameters of
the current switch.
<SW4500>display schedule reboot
System will reboot at 03:41 2000/04/02 (in 1 hours and 27 minutes).
reboot Syntax
reboot [ unit unit-id ]
View
User view
Parameter
unit unit-id: Specify the Unit ID of the switch
Description
Use the reboot command to reset the Switch when failure occurs.