3Com 4500 50-PORT Switch User Manual


 
394 CHAPTER 12: USING SYSTEM MANAGEMENT COMMANDS
RMON Configuration
Commands
This section describes the Remote Monitoring (RMON) configuration commands
available on your Switch 4500.
display rmon alarm Syntax
display rmon alarm [ alarm-table-entry ]
View
All views
Parameter
alarm-table-entry: Alarm table entry index.
Description
Use the display rmon alarm command to view RMON alarm information.
For the related commands, see rmon alarm.
Example
Display the RMON alarm information.
<SW4500>display rmon alarm
Alarm table 1 owned by 3COM is VALID.
Samples absolute value : 1.3.6.1.2.1.16.1.1.1.4.1
<etherStatsOctets.1>
Sampling interval : 10(sec)
Rising threshold : 1000(linked with event 1)
Falling threshold : 100(linked with event 1)
When startup enables : risingOrFallingAlarm
Latest value : 0
display rmon event Syntax
display rmon event [ event-table-entry ]
Table 40 Output description of the display rmon alarm command
Field Description
Alarm table 1 Index 1 in the alarm table
3Com Owner
VALID The entry corresponding to the index is valid
Samples absolute value Sampling the absolute value of the node
1.3.6.1.2.1.16.1.1.1.4.1
Sampling interval The interval of sampling the value
Rising threshold1 Rising threshold. When sampling value rises from
normal value to this threshold, rising threshold alarm
will be triggered.
Falling threshold Falling threshold. When sampling value decreases from
normal value to this threshold, falling threshold alarm
will be triggered.
startup The first trigger
risingOrFallingAlarm The type of the first alarm: Specifies to alarm when
exceeding the rising threshold or the falling threshold