3Com DUA1750-2BAA01 Switch User Manual


 
3Com Switch 8800 Configuration Guide Chapter 46 System Maintenance and Debugging
46-26
Note:
Info-center is enabled by default. After info-center is enabled, system performances are
affected when the system processes much information because of information
classification and outputting.
2) Configuring to output information to SNMP NM
Perform the following configuration in system view.
Table 46-43 Configure to output information to SNMP NM
Operation Command
Output information to SNMP NM
info-center snmp channel
{ channel-number | channel-name }
Cancel the configuration of outputting
information to SNMP NM
undo info-center snmp channel
3) Configuring information source on the switch
By this configuration, you can define the information that sent to SNMP NM is
generated by which modules, information type, information level, and so on.
Perform the following configuration in system view:
Table 46-44 Define information source
Operation Command
Define information source
info-center source { modu-name |
default } channel { channel-number |
channel-name } [ debug { level severity |
state state }* | log { level severity | state
state }* | trap { level severity | state
state }* ]*
Cancel the configuration of information
source
undo info-center source { modu-name
| default | all } channel
{ channel-number | channel-name }
modu-name specifies the module name; default represents all the modules; all
represents all the information filter configuration in channelnum chunnel except default
level refers to the severity levels; severity specifies the severity level of information.
The information with the level below it will not be output. channel-number specifies the
channel number and channel-name specifies the channel name.
When defining the information sent to SNMP NM, channel-number or channel-name
must be set to the channel that corresponds to SNMP direction.