AMX NXD-500i Computer Monitor User Manual


 
Introduction
4
NXD-500i 5" Wall/Flush Mount Touch Panel with Intercom
Specifications for NCXC-500i 5" Widescreen Video Touch Panel (Cont.)
Supported Audio Sample
Rates:
48000Hz, 44100Hz, 32000Hz, 24000Hz, 22050Hz, 16000Hz, 12000Hz,
11025Hz, and 8000Hz.
Intercom: Full duplex VoIP capabilities.
Front Panel Components:
Light sensor: Motion-sensitive light detector for automatic adjustment of the panel
brightness (a dim room results in a dimmer LCD display, and a bright room
results in a brighter LCD display).
Note: The light sensor can be adjusted via the Sensor Setup page (page 64).
Motion sensor (PIR): Proximity Infrared Detector to wake the panel when the panel is approached.
Activation range: +
25° (left and right from center) and + 15° (up and down
from center).
Note: This sensor can be adjusted via the Sensor Setup page (see page 64).
Front Bezel button: Provides both access to the Setup and Calibration page and toggles the
panel between a "sleep" or "wake" state. "Sleep" status means the backlight
is Off.
Microphone: Frequency response of 300 to 3400Hz
Used for intercom applications
Speaker: Output of 4Ohm
2 Watts
300Hz cutoff frequency
Side Panel Components:
Ethernet 10/100 port: RJ-45 port for 10/100 Mbps communication. The Ethernet port automatically
negotiates the connection speed (10 Mbps or 100 Mbps), and whether to use
half duplex or full duplex mode. Power is supplied through Power Over
Internet (PoE)
NXD-500i panels communicate with the NetLinx Master using the ICSP
protocol over Ethernet.
LEDs show communication activity, connections, speeds, and mode
information:
L/A-link/activity - yellow LED lights On when the Ethernet cables are
connected and terminated correctly and then blinks when receiving Ethernet
data packets.
SPD-speed - Green LED lights On when the connection speed is 100 Mbps
and turns Off when the speed is 10 Mbps.
Mini-USB connector: 5-pin Mini-USB connector used for programming, firmware update, and touch
panel file transfer between the PC and the target panel. The connector is
also used for providing audio output for external speakers.
Note: When connecting the panel to PC using a CC-USB (or compatible)
cable, be sure to power the panel On before attempting to connect the USB
cable from the PC to the mini-USB port on the panel. Refer to the Configuring
and Using USB with a Virtual Master section on page 25 for more information.
Button Assignments: Button assignments can only be adjusted in TPD4 and not on the panel.
Button channel range: 1 - 4000 button push and feedback (per address port)
Button variable text range: 1 - 4000 (per address port)
Button states range: 1 - 256 (General Button; 1 = Off State, 2 = On State)
Level range: 1 - 600 (default level value 0-255, can be set up to 1-65535)
Address port range: 1 - 100
Operating / Storage
Environment:
Operating Temperature: 0° C (32° F) to 40° C (104° F)
Operating Humidity: 5% - 85% relative humidity (non-condensing)
Storage Temperature: -20° C (-4° F) to 60° C (140° F)
Storage Humidity: 5% - 85% RH