AMX TVM-1600 Switch User Manual


 
Installation
7
TVM-1600 Endeleo Managed TV Distribution Hub
Powering off the TVM-1600
Flick the power switch up to its Off (0) position.
Connecting the TVM Receive Units to the TVM-1600
1.
Connect a Cat5 (or appropriate cable) to a port on the TVM-1600.
2. Run the cable to the TVM-RX03 and connect at the Cat5 port.
Connecting the Receive Units to the display devices
Connect the Endeleo Receive Units to the display devices using the appropriate cables and connections;
Video;
Audio;
Serial (if using a serial display device) and
Infra-red Tx blaster, to issue IR controls to the display device e.g. power off, on etc.
Ensure a TV channel can be displayed on the display device to ensure a good connection and
configuration with the TVM-1600.
Where a mains plug (or appliance coupler) is used in the event of a fault, the TVM-
1600 can be disconnected from the mains by removing the lead from the IEC inlet or
from the mains socket. It is important that the TVM-1600 is installed in such a way
that this method remains readily operable. The user should have easy access to
either the IEC inlet or the mains socket in the event of a fault.
FIG. 6 Cat5 (MTV) port on TVM-RX03
Cat5 (5e, 6, etc.) port
(front)
(rear)
When the TVM-1600 is powered on, an LCD illuminates on the front of the TVM-
RX03.