AMX UDM-1604 Switch User Manual


 
Installation
5
UDM-1604 Endeleo Multi-Format Distribution Hub
Installation
Overview
The UDM-1604 occupies a single rack space in a standard 19" equipment rack. Rack mounting brackets
and screws are located in the accessories box supplied with the UDM-1604.
Rack mounting brackets and screws are located in the accessories box supplied with the UDM-1604.
1. Attach the rack mounting brackets to each side of the UDM-1604 using four M4 screws for each
bracket (FIG. 2).
2. Place the UDM-1604 in the Rack and hold steady.
3. Two fixing holes are supplied on each side of the UDM-1604. Screw the hub into the rack using the
fixing holes (FIG. 3).
Ventilation
ALWAYS ensure that the rack enclosure is adequately ventilated.
Sufficient airflow must be achieved (by convection or forced-air cooling) to satisfy the ventilation
requirements of all the items of equipment installed within the rack.
Exercise extreme care when lifting or moving the hub within the rack to avoid injury. It
is recommended that you seek the assistance of another person when rack mounting
the UDM-1604.
FIG. 2 Attach the mounting brackets to each side of the Hub
To prevent injury the Hub must be securely attached to the rack in accordance with
the installation instructions.
ALWAYS use the special rack mount brackets supplied and high quality fixing screws
to ensure the hub is installed in the rack correctly.
FIG. 3 Screw the hub into the rack using the fixing holes
DO NOT stand other units directly on top of the hub when it is rack mounted, as this
will place excessive strain on the mounting brackets.