Removing and replacing disk drives
38 Avaya CMS R12 Sun Enterprise 3500 Computer CMS Upgrade Express
Verifying that the system recognizes the new boot disk drive
To verify that the system recognizes the new boot disk drive:
1. Enter:
format
A message similar to the following is displayed:
The message displays the boot disk drive.
2. Enter: 0
3. Enter: q
4. Continue with Checking the status of the boot disk drive
on page 38.
Checking the status of the boot disk drive
To check the status of the boot disk drive:
1. Enter:
. /opt/informix/bin/setenv
2. Enter:
onstat -d | egrep "On-Line"
A message similar to the following is displayed. If the boot disk is not on-line, escalate
through normal channels.
3. Continue with Checking the status of the tape drives
on page 39.
Searching for disks...done
AVAILABLE DISK SELECTIONS:
0. c0t0d0 <SUN36G cyl 24620 alt 2 hd 27 sec 107>
/sbus@X,0/SUNW,socal@d,10000/sf@0,0/ssd@w<WWN>,0
Specify disk (enter its number):
Informix Dynamic Server Version 9.40.UC1 -- On-Line -- Up
00:03:46 -- 78848 Kbytes