Avaya CPSEE_TSP500 Switch User Manual


 
Chapter 6 Trunk Spans and Dialing Rules
Page 6-6 Version 4.0 CPSEE_TSP500 User Guide
This document is confidential and proprietary to SER Solutions and is not for external use.
This keyword specifies the time (in seconds) that the AMD analysis will look
for the beep at the end of the Answering Machine. If timeout occurs, the TSP
will consider that the beep has been heard and play the appropriate ENCORE
message. This analysis only takes place if an ENCORE message is specified
to be played to Answering Machines detected during a specific campaign.
The default is twenty seconds, and should not be changed unless advised to
do so by Engineering.
ANSM_USETONE
This keyword specifies the method to be used for detecting when to play
Encore messages to answering machines. The default value of this keyword
is zero.
ANSM_USETONE 0
Wait for a period of silence before playing the message.
ANSM_USETONE 1
Wait for the beep, and then wait a little longer to ensure it was the last beep.
AREACODE_DIGITS
This keyword defines the number of digits in the area code where the TSP is
installed. For the USA this would be set to “3.” For other countries, you
should set it appropriately.
See Also:
Keyword ANSM_SILENCE.