Avaya CPSEE_TSP500 Switch User Manual


 
Chapter 4 Features and Enhancements
Page 4-22 Version 4.0 CPSEE_TSP500 User Guide
This document is confidential and proprietary to SER Solutions and is not for external use.
assigned.
The Admin Terminal command “spstuff" displays “Monitor has
Assigned Station List”, if a monitor has been restricted via the
MONITOR_ASSIGN keyword.
Enter Command-> sp 169
Station # 169 Matrix: 0000082c
mvip: board: 0 st: 9 ts: 20 <-- 7fff
local: board: 3 st:28 ts: 0 <-- 7fff
Dsp 1189 Assigned
Dsp is listening to MTX 82c
Queue = stinact
Digital Station (trunk=937)
Phone On Hook
This Station has Manual Monitor Capability
Monitor has Assigned Station List
sflags = [8100] tflags = [0] zflags = [0]
preview queue: current: 0 Peak: 0
Decibel Level Adjustment - Feature
When performing Client Monitoring, the audio level of the monitored call
tends to be lower than that of the Client, and Supervisor. A new keyword has
been added to the Dialing Rules (CLIMON_GAIN) that will specify some
decibel level to increase the volume of the monitored call. The default gain at
present is 6db. If customers are complaining of low volume when doing Cli-
ent Monitoring, add this keyword and type “load all” in the Admin Terminal.
The range of adjustment is 0db through 12db.
Example: CLIMON_GAIN 9
The above assignment would raise the volume of the monitored call by 9db.