Brocade Communications Systems RFS7000 Network Router User Manual


 
298 Brocade Mobility RFS4000, RFS6000 and RFS7000 CLI Reference Guide
53-1001931-01
Global Configuration commands
5
min-packets <1-65535> – Minimum packets
required for sending the trap
<1-65535> – Defines the minimum packets for
sending the trap. This can be set with a decimal
number in the range of <1-65535>
wireless-client [avg-bit-speed-less-than|
avg-retry-greater-than|avg-signal-less-than|
gave-up-percent-greater-than|
nu-percent-greater-than|pktsps-greater-than|
tput-greater-than|
undecrypt-percent-greater-than] – Modifies
wireless-client rate traps
avg-bit-speed-less-than – Average bit speed in
Mbps is between <0.00> and <54.00>
avg-retry-greater-than – Average retry is greater
than 0.00 and less than or equal to 16.00
avg-signal-less-than – Average signal in dBm is
less than -0.00 and greater than or equal to
-120.00
gave-up-percent-greater-than – Percentage of
pkts dropped is greater than 0.00 and less than
or equal to 100.00
nu-percent-greater-than – Percentage of
non-unicast pkts is greater than 0.00 and less
than or equal to 100.00
pktsps-greater-than – Packets per sec is greater
than 0.00 and less than or equal to 100000.00
tput-greater-than – Throughput in Mbps is
greater than 0.00 and less than or equal to
100000.00
undecrypt-percent-greater-than – Percentage of
undecryptable pkts is greater than 0.00 and
less than or equal to 100.00
engineid [netsnmp {<word>}|
text <word>]
Sets the SNMP server engine ID.
netsnmp <word>– Sets the engine id to a
hexadecimal string
text <word> – Sets the engine id to a text string
host <IP> [v2c|v3] {<1-65535>} SNMP server host.
<IP> – SNMP server host IP address
v2c <1-65535> – Use snmp version 2c
v3 <1-65535> – Use snmp version 3
location <location-text> Text for mib object sysLocation.
manager [all|v2|v3] Enables the SNMP manager.
all – Enables SNMP version v2 and v3
v2 – Enables SNMP version v2
v3 – Enables SNMP version v3
periodic-heartbeat-interval
<interval>
Sets periodic heartbeat trap interval. A periodic trap is
sent if no other traps are sent by the controller. The
default time period is 60 seconds. Set a value to between
10 and 1000 seconds.