Cisco Systems 1550 Computer Accessories User Manual


 
2-56
Cisco Aironet 1550 Series Outdoor Mesh Access Point Hardware Installation Guide
OL-24247-01
Chapter 2 Installing the Access Point
Powering the Access Point
Figure 2-41 Location of the DC Power Liquid-Tight Adapter
Step 4
Loosen the round end of the liquid-tight adapter by turning counterclockwise, but do not remove (see
Figure 2-42).
Figure 2-42 Liquid-Tight Adapter
Note The liquid-tight adapter accepts a cable diameter of 0.20 to 0.35 in. (0.51 to 0.89 cm).
Step 5 Insert a bare end of the DC power cable into the rounded end of the liquid-tight adapter (see
Figure 2-42), and pull approximately 6 inches of cable through the adapter.
Step 6 Strip the DC cable jacket back about 1 inch to expose the wires and strip the insulation about 3/8 inch
(9.5 mm) from each wire.
Step 7 Insert each wire into the two-position terminal strip (supplied), and tighten each wire using a 0.1 inch
(0.25 cm) flat screw driver (see Figure 2-43).
1 DC power connector with liquid-tight adapter 2 Ground lug screw holes
255240
1
2
1 Thread end 2 Round end