Powering the Access Point
Table 2-4 AC Power Cord Information
When using a user-supplied AC power plug on the AIR-CORD-R3P-40UE= power cord, ensure that the
plug is certified for outdoor use and that it has a minimum IP67 rating, such as Interpower 84131251 or
Hubbell HBL316P6W (IEC/EN 60309) pin-and-sleeve type connectors. The European Union power
cord plug pinouts are listed in Figure 2-37. For the location of the AC power connectors, see Figure 2-39
and Figure 2-40.
Figure 2-37 European Union Plug Pinouts
Caution All AC power plugs and AC receptacles must be protected from water and other outdoor elements. Use
a UL listed waterproofing enclosure suitable for covering the AC receptacle and AC power plug that
supplies power to the unit as described in Article 406 of the NEC. If the power cord goes through a metal
cover, install a bushing to prevent fraying of the cord.
When using a strain relief bushing, you should follow these recommendations:
Use properly sized parts (see Table 2-4 for the power cord diameter)
Use bushings that are safety certified
Use parts that are suitable for outdoor installation
Caution If your power cord does not use an AC power plug, you must ensure that the power source is OFF before
connecting or disconnecting the power cord wires from the power source.
AC Power Cord Cord Diameter Comment
AIR-CORD-R3P-40NA= 0.398 to 0.413 in.
(10.1 mm to 10.5 mm)
The three prong plug is limited to 120 VAC.
Internal wiring is rated at 600 VAC insulation
protection.
AIR-CORD-R3P-40UE= 0.398 to 0.413 in.(10.1 mm
to 10.5 mm)
Power cord rating is 100 to 480 VAC. Internal
wiring is 16 AWG.
AIR-PWR-ST-LT-TAP= Strain relief bushing not
needed
Power cord rating is 100 to 480 VAC
Pin Description Conductor Color Pin Description Conductor Color
1 Ground Green/Yellow 3 Neutral Blue
2 Live Brown
1
3
2
255269