Compex Systems SA33-3285-02 Network Card User Manual


 
Installing a Replacement Disk Drive
1. Physically install the replacement disk drive (see the Operator Guide or Service
Guide for the unit).
2. If the failed disk drive has been exchanged for a hot spare disk drive, change the
use of the new disk drive to Hot Spare Disk (see Changing or Showing the Use
of an SSA Disk Driveon page 144). Run system diagnostics to verify that the disk
drive is working correctly.
If no hot spare disk drive was available when the original disk drive failed, the
array is now in the Exposed state or in the Degraded state. Change the use of the
new disk drive to Array Candidate Disk (see Changing or Showing the Use of an
SSA Disk Driveon page 144), and continue with this procedure to add the new
disk drive to the array.
3. For fast path, type smitty exssaraid and press Enter.
Otherwise:
a. Select Change Member Disks of an SSA RAID Array from the SSA RAID
Arrays menu.
b. Select Swap Members of an SSA RAID Array.
4. A list of arrays is displayed:
Change Member Disks of an SSA RAID Array
Move cursor to desired item and press Enter.
Remove a Disk from an SSA RAID Array
Add a Disk to an SSA RAID Array
Swap Members of an SSA RAID Array
--------------------------------------------------------------------------
| SSA RAID Array |
| |
| Move cursor to desired item and press Enter. |
| |
| hdisk3 00703795D3F7C0G system good 9.2GB raid_1 |
| hdisk4 00703784C540C0O system degraded 27.5GB raid_10 |
| hdisk5 007037943540C0O system good 27.5GB raid_10 |
| |
| F1=Help F2=Refresh F3=Cancel |
| F8=Image F10=Exit Enter=Do |
| /=Find n=Find Next |
--------------------------------------------------------------------------
Select the array into which you are installing the replacement disk drive. This array
is listed as exposed or degraded.
Chapter 6. Using the RAID Array Configurator 95