v Have a size equal to, or greater than, the largest disk drive that they will
be protecting
v Are in pool 0 on the SSA loop on which the hot spare pool exists
2. If you are not sure whether your disk drives are assigned correctly:
a. Ensure that the required number of disk drives of the correct size are
assigned as hot spare disk drives, or as array candidate disk drives
(see Changing the Use of Multiple SSA Physical Diskson page 147).
b. Ensure that the disk drives that you are planning to use are in pool 0
(see Listing the Disks That Are in a Hot Spare Poolon page 80).
3. Add the required number of disk drives to the pool (see Adding Disks to,
or Removing Disks from, a Hot Spare Poolon page 86).
Reduced
The number of hot spare disk drives that are in the pool is less than the
number of hot spare disk drives that were in the pool when the pool was last
configured, but greater than the minimum number that is specified for this pool.
This condition does not cause an error to be logged.
If you removed a disk drive from the configuration on purpose:
1. Select Change/Show/Delete a Hot Spare Pool from the smit ssaraid
menu (see Adding Disks to, or Removing Disks from, a Hot Spare Pool
on page 86).
2. Select the reduced hot spare pool.
3. Verify that the contents of the pool are as required.
4. Press Enter.
If you have exchanged a failed disk drive, you might now want to add the
exchanged disk drive to this pool (see Adding Disks to, or Removing Disks
from, a Hot Spare Poolon page 86).
Critical The number of hot spare disk drives that are in the pool is less than the
specified minimum number for that pool.
If you removed a disk drive from the configuration on purpose:
1. Select Change/Show/Delete a Hot Spare Pool from the smit ssaraid
menu (see Adding Disks to, or Removing Disks from, a Hot Spare Pool
on page 86).
2. Select the critical hot spare pool.
3. Verify that the contents of the pool are as required.
4. Press Enter.
If you have exchanged a failed disk drive, you must now add the exchanged
disk drive to this pool (see Adding Disks to, or Removing Disks from, a Hot
Spare Poolon page 86).
54 Users Guide and Maintenance Information