d. Select the pdisk from the list, and change the Current Use parameter
to Array Candidate Disk.
e. Select Change Member Disks in an SSA RAID Array.
f. Select Swap Members of an SSA RAID Array.
g. Select the hdisk that is in the Degraded copy state (that is, the hdisk
that you noted in step 23d on page 467).
h. Referring to the displayed instructions, select a disk drive to remove
from the array, and the disk drive to add to the array. (The disk drive
to remove is listed as not_present; the disk drive to add is the disk
drive that you reinstalled or selected in step 26a on page 468.) When
the exchange is complete, the array starts to copy its data to the
coupled disk drive.
i. Go to MAP 2410: SSA Repair Verificationon page 475 to verify the
repair.
YES
a. Exchange the failed disk drive for a new one (see Exchanging Disk
Driveson page 319).
b. Type smitty ssaraid and press Enter.
c. Select Change/Show Use of an SSA Physical Disk. The pdisk that
has been exchanged is listed under SSA Physical Disks that are
system disks.
d. Select the pdisk from the list, and change the Current Use parameter
to Array Candidate Disk.
e. Select Change Member Disks in an SSA RAID Array.
f. Select Swap Members of an SSA RAID Array.
g. Select the hdisk that is in the Degraded copy state (that is, the hdisk
that you noted in step 23d on page 467).
h. Referring to the displayed instructions, select a disk drive to remove
from the array, and the disk drive to add to the array. (The disk drive
to remove is listed as not_present; the disk drive to add is the disk
drive that you exchanged in the previous steps.) When the exchange
is complete, the array starts to copy its data to the coupled disk drive.
i. Go to MAP 2410: SSA Repair Verificationon page 475 to verify the
repair.
Chapter 18. SSA Problem Determination Procedures 469
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|