SRN Problem Possible Causes
50002 Description: An SSA adapter DMA error has occurred.
Action: Exchange the FRU for a new FRU.
Possible FRUs:
SSA adapter card (100%)
(Removing and Replacing
an Advanced SerialRAID
Adapteron page 327).
50007 Description: The IOCC detected an internal error.
Action: Exchange the FRU for a new FRU.
Possible FRUs:
SSA adapter card (100%)
(Removing and Replacing
an Advanced SerialRAID
Adapteron page 327).
50008 Description: Unable to read or write the POS registers or PCI
configuration space.
Action: Exchange the FRU for a new FRU.
Possible FRUs:
SSA adapter card (100%)
(Removing and Replacing
an Advanced SerialRAID
Adapteron page 327).
50010 Description: An SSA adapter or device drive protocol error has occurred.
Action: Go to Software and Microcode Errorson page 441 before
exchanging the FRU.
Possible FRUs:
SSA adapter card (100%)
(Removing and Replacing
an Advanced SerialRAID
Adapteron page 327).
50012 Description: The SSA adapter microcode has hung.
Action: Run diagnostics in System Verification mode to the SSA adapter.
If the diagnostics fail, exchange the FRU for a new FRU.
If the diagnostics do not fail, go to Software and Microcode Errorson
page 441 before exchanging the FRU.
Possible FRUs:
SSA adapter card (100%)
(Removing and Replacing
an Advanced SerialRAID
Adapteron page 327).
50013 Description: The SSA adapter card has failed.
Action: Exchange the FRU for a new FRU.
Possible FRUs:
SSA adapter card (100%)
(Removing and Replacing
an Advanced SerialRAID
Adapteron page 327).
50100 Description: An attempt was made to log an error against a pdisk that is
not available to the using system.
Action: This problem has occurred for one of the following reasons:
v A user has deleted a pdisk from the system configuration. In such an
instance, the hdisk that is using the pdisk continues to operate
normally. If the disk drive tries to log an error, however, this SRN
(50100) is produced. Give the cfgmgr command to return the pdisk to
the system configuration.
v A device has tried to log an error during system configuration. To find
the failing device, run diagnostics to the devices that are connected to
this SSA adapter.
Disk drive error during system
configuration.
Chapter 18. SSA Problem Determination Procedures
435
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|