Chapter 15. Removal and Replacement Procedures
Exchanging Disk Drives
1. If you are removing a disk drive under concurrent maintenance (see the service
information for the device that contains the disk drive), you must first determine
which hdisk is using the pdisk that you want to remove. To do this, you can either
use the Configuration Verification service aid (see Configuration Verification
Service Aidon page 387), or give the ssaxlate command from the command line
(see ssaxlate Commandon page 372).
v If no hdisk is using the pdisk, go to step 13 on page 323.
v If an hdisk is using the pdisk, you must now determine the type of the hdisk.
The hdisk might be an SSA disk drive or a RAID disk. To determine whether the
hdisk is a RAID disk, type:
smitty lsdssaraid
A list is displayed of all hdisks that are configured as RAID arrays.
If an hdisk that is a RAID-1, RAID-5, or RAID-10 array is using the pdisk, you
can remove the disk drive from the array. Go to step 7 on page 322.
If an hdisk that is a RAID-0 array is using the pdisk:
a. Ask the customer to make a backup of the data (if possible) from the
array, and to make the disk free.
b. Ensure that you delete the array before you exchange the pdisk.
c. Note the hdisk number.
d. Go to step 2.
v If the hdisk is not a RAID pdisk:
a. Ask the customer to make a backup of the data (if possible) from the array,
and to make the disk free.
b. Ensure that the fast-write function is disabled (see Enabling or Disabling
Fast-Write for One Disk Driveon page 214).
c. Go to step 13 on page 323.
2. Attention: You should be here only if you are working with a RAID-0 array.
For fast path, type smitty rmssaraid and press Enter.
Otherwise, select Delete an SSA RAID Array from the SSA RAID Array menu.
A list of arrays is displayed in a window:
319