The following information is displayed for RAID-1 and RAID-10 arrays:
COMMAND STATUS
Command: OK stdout: yes stderr: no
Before command completion, additional instructions may appear below.
Components
Primary Secondary Status
hdisk4 degraded
pdisk13 pdisk15 good
pdisk3 pdisk6 good
pdisk7 BlankReserved5Z degraded
F1=Help F2=Refresh F3=Cancel F6=Command
F8=Image F9=Shell F10=Exit /=Find
n=Find Next
Status data is given for the array and for each mirrored pair of disk drives in the
array. The status values for the array are:
good The status of all mirrored pairs is good.
exposed
The status of one or more mirrored pairs is exposed. No mirrored pair is
degraded.
degraded
The status of one or more mirrored pairs is degraded.
rebuilding
The status of one or more mirrored pairs is rebuilding. No mirrored pair is
exposed or degraded.
offline One of the following conditions exists:
v The status of one or more mirrored pairs is offline.
v The first two member disk drives of the primary half are missing, and the
Split Array Resolution flag is set to Primary.
v The first member disk drive of the secondary half is missing, and the
Split Array Resolution flag is set to Secondary.
unknown
Not enough configuration data is available to determine the state of the
array. Under these conditions, ignore the primary and secondary
designations and the array-pair status.
The status values for mirrored pairs are:
good Both member disk drives of the mirrored pair are present and working.