Compex Systems SA33-3285-02 Network Card User Manual


 
SRN Problem Possible Causes
1xxxx Description: SRNs in this range are not adapter SRNs.
Action: For SRNs in this range, see the documentation for your SSA
enclosure or SSA subsystem.
Not applicable.
20PAA Description: An open SSA link has been detected.
Action: Run the Link Verification service aid to isolate the failure (see
Link Verification Service Aidon page 383).
If the SSA service aids are not available, go to the service information for
the enclosure in which the device is installed
Possible FRUs:
Device (45%) (Exchanging
Disk Driveson page 319).
SSA adapter card (45%)
(Removing and Replacing
an Advanced SerialRAID
Adapteron page 327).
External SSA cables (6%).
Internal SSA connections
(4%) (enclosure service
information).
21PAA
to
29PAA
Description: An SSA Threshold exceededlink error has been detected.
Action: Go to MAP 2323: SSA Intermittent Link Erroron page 450.
Possible FRUs:
Device (45%)(Exchanging
Disk Driveson page 319).
SSA adapter card (45%)
(Removing and Replacing
an Advanced SerialRAID
Adapteron page 327).
External SSA cables (6%).
Internal SSA connections
(4%) (enclosure service
information).
2A002 Description: Async code 02 has been received. Probably, a software error
has occurred.
Action: Go to Software and Microcode Errorson page 441 before
exchanging any FRUs.
Possible FRUs:
Device (50%) (Exchanging
Disk Driveson page 319).
SSA adapter card (50%)
(Removing and Replacing
an Advanced SerialRAID
Adapteron page 327).
2A003 Description: Async code 03 has been received. Probably, a software error
has occurred.
Action: Go to Software and Microcode Errorson page 441 before
exchanging any FRUs.
Software error.
Possible FRUs:
Device (50%) (Exchanging
Disk Driveson page 319).
SSA adapter card (50%)
(Removing and Replacing
an Advanced SerialRAID
Adapteron page 327).
Chapter 18. SSA Problem Determination Procedures
413
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|