Compex Systems SA33-3285-02 Network Card User Manual


 
5. The following information is displayed:
Swap Members of an SSA RAID Array
Type or select values in entry fields.
Press Enter AFTER making all desired changes.
[Entry Fields]
SSA RAID Manager ssa1
SSA RAID Array hdisk4
RAID Array Type raid_10
Connection Address / Array Name 00703784C540C0O
* Disk To Remove +
* Disk To Add +
F1=Help F2=Refresh F3=Cancel F4=List
F5=Reset F6=Command F7=Edit F8=Image
F9=Shell F10=Exit Enter=Do
6. Select Disk to Remove.
7. Press the List key to display the disk drive to remove. If the disk drive that you are
replacing has been rejected by the array, that disk drive is listed as
BlankReservedZ.
8. Select the required disk drive, and press Enter.
9. Select Disk to Add.
10. Press the List key to display the disk drive to add. Disk drives that are free or hot
spare disk drives are listed.
11. Select the required disk drive, and press Enter.
12. Press Enter to perform the swap operation.
96 Users Guide and Maintenance Information