Compex Systems SA33-3285-02 Network Card User Manual


 
Effects of Array Copy on Other SMIT Menus
This section shows SMIT menus that are described elsewhere in this book. When Array
Copy is used, however, additional fields or display panels are present.
Change/Show Attributes of an SSA RAID Array
The following information is displayed for RAID-1 or RAID-10 arrays:
Change/Show Attributes of an SSA RAID Array
Type or select values in entry fields.
Press Enter AFTER making all desired changes.
[TOP] [Entry Fields]
SSA RAID Manager ssa1
SSA RAID Array hdisk2
Connection Address / Array Name 8A8E39195F60C4O
RAID Array Type raid_10
State good
Copy State copying
Size of Array 18.2GB
Primary Disks pdisk0 pdisk6
Secondary Disks pdisk9 pdisk10
Copy Disks pdisk11 pdisk12
Percentage Rebuilt Not Rebuilding
Percentage Copied 1
Split Array Resolution Primary +
Enable Use of Hot Spares yes +
[MORE...4]
F1=Help F2=Refresh F3=Cancel F4=List
F5=Reset F6=Command F7=Edit F8=Image
F9=Shell F10=Exit Enter=Do
The meanings of the additional fields are:
Copy State
The operational state of the array copy:
Not Copying
No copy is being created for this array.
Good The coupled disk drives contain an exact copy of the data that is on
the array. The copy must be in the Good state before it can be
uncoupled from the array.
Copying
Data is being copied to the coupled disk drives, but these coupled
disk drives do not yet contain an exact copy of the data that is on the
array.
Degraded
A copy has been created, but one or more coupled disk drives are
missing or have failed. If missing disk drives are replaced or
exchanged for new disk drives, the copy operation continues.
Coupled Disks
The disk drives that are coupled to the array and contain the copy of the array
data. These disk drives are present only if an array copy has been created.
186 Users Guide and Maintenance Information
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|