Dell 4100/200 Personal Computer User Manual


 
7-18 Dell PowerEdge 4100/180 and 4100/200 Systems Installation and Troubleshooting Guide
5. Turn off the system, including any attached
peripherals, and disconnect all the AC power
cables from their power sources.
6. Remove both computer covers.
See Removing the Computer Covers found earlier
in this chapter.
7. Check the SCSI cable connections to the tape
drive and to the SCSI host adapter connector. If
the tape drive is an internal device, check the DC
power cable connection to the tape drive.
Are the cables firmly connected?
Ye s . Go to step 9.
No. Go to step 8.
8. Reseat the cable connectors, replace the computer
covers, reconnect the system to AC power, and
turn it on.
Is the problem resolved?
Ye s . You have fixed the problem.
No. Go to step 9.
9. Turn off the system, including any attached
peripherals, and disconnect all the AC power
cables from their power sources. Then remove the
right computer cover.
10. Remove the tape drive. Then verify that the tape
drive is configured for a unique SCSI identifica-
tion (ID) number and that the tape drive is
terminated or not terminated as appropriate.
See the documentation for the tape drive for instruc-
tions on selecting the SCSI ID and enabling or
disabling termination.
Is the tape drive configured correctly?
Ye s . Go to step 13.
No. Go to step 11.
11. Reconfigure the tape drives SCSI ID and termi-
nation settings as appropriate. Reinstall the tape
drive, replace the computer covers, reconnect the
system to AC power, and turn it on.
Is the problem resolved?
Ye s . The tape drive was configured incorrectly. You
have fixed the problem.
No. Go to step 12.
12. Turn off the system, including any attached
peripherals, and disconnect all the AC power
cables from their power sources. Then remove the
computer covers.
13. Replace the SCSI cable that connects the tape
drive to the SCSI host adapter. Replace the com-
puter covers, reconnect the system to AC power,
and turn it on.
Is the problem resolved?
Ye s . You have fixed the problem.
No. See Chapter 11, Getting Help, for instructions
on obtaining technical assistance.
T
roubleshooting SCSI Hard-Disk
Drives
Hard-disk drive problems can be caused by a number of
conditions, including problems with the drive itself, the
SCSI backplane board, or an interface cable.
Drive Indicator Error Codes
The SCSI backplane board monitors the internal SCSI
hard-disk drives connected to the backplane board. In the
event of a drive failure, systems using the optional Dell
PowerEdge Expandable RAID Controller will issue the
following signals using the drive indicator lights adjacent
to each SCSI hard-disk drive:
If a drive shows signs of imminent failure, the drive
online indicator turns off and the drive fault indicator
blinks on briefly each second.
If a drive has failed, the drive online indicator turns
off and the drive fault indicator blinks off briefly
each second.
Other drive indicator patterns are listed in SCSI Hard-
Disk Drive Indicator Codes in Chapter 3.
CAUTION: See Protecting Against Electro-
static Discharge in the safety instructions at
the front of this guide.