Epson EPL-6200 All in One Printer User Manual


 
EPSON EPL-6200/EPL-6200L Revision A
Troubleshooting Troubleshooting for Abnormal Operations 120
3.4.2 Electrical Noise
Table 3-28. Troubleshooting for “Electrical Noise”
Step Action and Question Yes No
Parts below can be the source of this error (Chapter 4 Disassembly and Assembly)
Main Board Assy (C533/C534 Main) (p.146)
Power Supply Unit (PU1) (p.151)
Fuser Unit (p.152)
High Voltage Unit (HV1) (p.151)
Photoconductor Unit (p.135)
Developer Cartridge (p.135)
Paper Cassette Unit Control Board (p.162)
Duplex Unit Control Board (p.163)
1
External noise
1. Check to see if within 3 m from the printer there is
another electrical apparatus, such as a generator,
radio transmitter or an apparatus incorporating a
motor.
2. Turn off the power to the electrical apparatus in
question or move the printer to a position at least 6
m distant from the apparatus.
Does the problem with electrical noise still occur?
Go to Step 2
Problem
solved
2
AC grounding
Check the AC power connection.
Is the AC power cable connected and grounded
properly?
Go to Step 3
Ask the
customer for
repair of the
AC power
connection.
3
Grounding screw
Check the grounding screw of the AC Inlet.
Is the cable grounded properly?
Go to Step 4
Install the
grounding
screw
properly.
4
Photoconductor Unit (Drum Cartridge)/Developer
Cartridge (toner cartridge)
Replace the Photoconductor Unit or Developer
Cartridge.
Does the problem with electrical noise still occur?
Go to Step 5
Problem
solved
5
Continuity of cables
Check continuity of each cable.
Does each cable have continuity?
Go to Step 6
Replace the
defective
cable.
6
Grounding of circuit boards
Check grounding of circuit boards.
Is grounding ensured?
Go to Step 7
Ensure
grounding.
7
Fuser unit
Replace the fuser unit.
Does the problem still occur?
Go to Step8
Replace the
fuser unit.
8
High voltage unit
Replace the high voltage unit.
Does the problem still occur?
Go to Step9
Replace the
high voltage
unit.
9
Power supply unit
Replace the power supply unit.
Does the problem still occur?
Go to Step10
Replace the
power supply
unit.
10
Main Board Assy.
Replace the Main Board Assy.
Does the problem still occur?
Replace all
the relevant
parts.
Problem
solved
Table 3-28. Troubleshooting for “Electrical Noise” (continued)
Step Action and Question Yes No