Operating Principles Description of Mechanisms 84
TEMPERATURE CONTROL MODE
During printing, the fuser temperature is adjusted along the passage of time counted
from completion of warming up.
Mode 1:
Temperature control mode 1 continues for five minutes. However, the temperature
adjustment mode 1 that was interrupted once is resumed with the timer counting
from the count just before interruption, if the thermistor temperature is 50°C or
higher. Upon completion of temperature adjustment mode 1, temperature
adjustment mode 2 starts.
Mode 2:
This mode continues for 208 seconds. Once the printing temperature is lowered
gradually and has dropped to the printing temperature of temperature adjustment
mode 3, mode 2 is ended and temperature adjustment mode 3 is started.
Mode 3:
This mode continues until it is interrupted (for example, the front cover is opened).
PRINTING TEMPERATURE AT EACH TEMPERATURE ADJUSTMENT
MODE
Table 2-6. Printing Temperature at Each Temperature Adjustment Mode
Mode 1 Mode 2 Mode 3
600 dpi
Plain paper 200°C 200°C190°C 190°C
Thick paper, Envelopes,
Postcards
205°C215°C
Transparencies 195°C 195°C185°C 185°C
1200 dpi
Plain paper 160°C 160°C155°C 155°C
Thick paper, Envelopes,
Postcards
165°C170°C
Transparencies 155°C 155°C150°C 150°C