Epson EPL-6200 All in One Printer User Manual


 
EPSON EPL-6200/EPL-6200L Revision A
Product Description Basic Specifications 30
1.2.6 Storage and Transport of the Printer Main Unit and
Optional Products (Consumables Packaged)
Temperature and Humidity Conditions
Transportation Barometric Pressure
61.3 ~ 101.3 kPa or more (460 ~ 760 mmHg)
Dropping
No abnormalities according to JIS Z0200-1998 Level 1
Vibration
Frequency: 5 ~ 100Hz (Sweep time: 10 minutes)
Acceleration: 1G
Direction of application: 3 dimensional
Time of application: 60 minutes along each X, Y, Z axis,
180 minutes in total
1.2.7 Electrical Features
Fast Transient / Bursts (AC Line Noise)
IEC 61000-4-4 compliance
Voltage 1 k: no malfunction occurs such as defective image quality.
2 kV: no damage to parts allowed.
Instantaneous Outages
DIP 100% (at rated current - 10%) one cycle.
No effect on printing quality
Resistance to Static Electricity (IEC 61000-4-2 compliance)
Direct contact discharge: 4.5 kV
Indirect contact discharge: 4.5 kV
Aerial discharge: 8.5 kV
NOTE:
Even when electric discharge as mentioned above occurs, the printer shall
keep operating normally without any trouble which affects the basic
performance or which can lead to breakdown of the printer.
Inrush Current: 50 A or less (0-peak)
Insulation Resistance: 10 M or more (at DC 500 V)
Dielectric Strength
No break down during application of the voltages shown below for one minute.
Leak Current
Table 1-30. Temperature and Humidity Conditions
Temperature
(°C)
Humidity
(%RH)
Warranty Period Others
Normal
Conditions
0
35 3085 18 months
No condensation
Severe
Conditions
High temperature:
35
40
Low temperature:
-20
0
High humidity:
85
95
Low humidity:
10
30
1/30 of
warranty period.
Across primary and chassis
For 100 V models AC 1000 V
For 110 to 127 V models AC 1000 V
For 220 to 240 V models AC 1500 V
Intended Market Leak Current
100 V (Japan) 0.25 mA or less
110 to 127 V models 3.5 mA or less
220 to 240 V models 3.5 mA or less