GE EPM 9650/9800 Computer Monitor User Manual


 
Address Line Pt
DNP
Ob
j
Description Range Units Type R/W
04809-04812 355 0 20 obsolete-TOU Active Total Watthour (Quadrant 1 + 4) +9,999,999,999,999,999 Wh / 0 Wh
1 W
H
F20 R
04813-04816 355 1 20 obsolete-TOU Active Total VAhour (Quadrant 1) +9,999,999,999,999,999 VAh / 0 VAh
1 VA
H
F20 R
04817-04820 355 2 20 obsolete-TOU Active Total VARhour (Quadrant 1) +9,999,999,999,999,999 VARh / 0 VARh
1 VAR
H
F20 R
04821-04824 355 3 20 obsolete-TOU Active Total VAhour (Quadrant 4) +9,999,999,999,999,999 VAh / 0 VAh
1 VA
H
F20 R
04825-04828 355 4 20 obsolete-TOU Active Total VARhour (Quadrant 4) 0 VARh / -9,999,999,999,999,999 VARh
1 VAR
H
F20 R
04829-04832 355 5 20 obsolete-TOU Active Total Watthour (Quadrant 2 + 3) 0 Wh / -9,999,999,999,999,999 Wh
1 W
H
F20 R
04833-04836 355 6 20 obsolete-TOU Active Total VAhour (Quadrant 2) +9,999,999,999,999,999 VAh / 0 VAh
1 VA
H
F20 R
04837-04840 355 7 20 obsolete-TOU Active Total VARhour (Quadrant 2) +9,999,999,999,999,999 VARh / 0 VARh
1 VAR
H
F20 R
04841-04844 355 8 20 obsolete-TOU Active Total VAhour (Quadrant 3) +9,999,999,999,999,999 VAh / 0 VAh
1 VA
H
F20 R
04845-04848 355 9 20 obsolete-TOU Active Total VARhour (Quadrant 3) 0 VARh / -9,999,999,999,999,999 VARh
1 VAR
H
F20 R
04849-04850 356 0 30 TOU Active Total Peak Demand Watt (Quadrant 1 + 4) +32767 Watt / 0 Watt 1/ 65536 W sec F7 R
04851-04852 356 1 30 TOU Active Total Peak Demand Watt (Quadrant 2 + 3) 0 Watt / -32768 Watt 1/ 65536 W sec F7 R
04853-04854 356 2 30 TOU Active Total Peak Demand VAR (Quadrant 1 + 2) +32767 VAR / 0 VAR 1/ 65536 VAR sec F7 R
04855-04856 356 3 30 TOU Active Total Peak Demand VAR (Quadrant 3 + 4) 0 VAR / -32768 VAR 1/ 65536 VAR sec F7 R
04857-04858 357 0 30 TOU Active Total Coin. Dmd. VAR to Peak Dmd. Watt (Quadrant 1 + 4) +32767 VAR/ -32768 VAR 1/ 65536 VAR sec F7 R
04859-04860 357 1 30 TOU Active Total Coin. Dmd. VAR to Peak Dmd. Watt (Quadrant 2 + 3) +32767 VAR / -32768 VAR 1/ 65536 VAR sec F7 R
04861-04864 358 0 50 TOU Active Total Peak Demand Watt (Q 1 + 4) Time Stamp 12/31/9999 23:59:59.99 10 msec F3 R
04865-04868 358 1 50 TOU Active Total Peak Demand Watt (Q 2 + 3) Time Stamp 12/31/9999 23:59:59.99 10 msec F3 R
04869-04872 358 2 50 TOU Active Total Peak Demand VAR (Q 1 + 2) Time Stamp 12/31/9999 23:59:59.99 10 msec F3 R
04873-04876 358 3 50 TOU Active Total Peak Demand VAR (Q 3 + 4) Time Stamp 12/31/9999 23:59:59.99 10 msec F3 R
04877-04880 359 0 20 obsolete-TOU Current Month Reg 1 Watthour (Quadrant 1 + 4) +9,999,999,999,999,999 Wh / 0 Wh
1 W
H
F20 R
04881-04884 359 1 20 obsolete-TOU Current Month Reg 1 VAhour (Quadrant 1) +9,999,999,999,999,999 VAh / 0 VAh
1 VA
H
F20 R
04885-04888 359 2 20 obsolete-TOU Current Month Reg 1 VARhour (Quadrant 1) +9,999,999,999,999,999 VARh / 0 VARh
1 VAR
H
F20 R
04889-04892 359 3 20 obsolete-TOU Current Month Reg 1 VAhour (Quadrant 4) +9,999,999,999,999,999 VAh / 0 VAh
1 VA
H
F20 R
04893-04896 359 4 20 obsolete-TOU Current Month Reg 1 VARhour (Quadrant 4) 0 VARh / -9,999,999,999,999,999 VARh
1 VAR
H
F20 R
04897-04900 359 5 20 obsolete-TOU Current Month Reg 1 Watthour (Quadrant 2 + 3) 0 Wh / -9,999,999,999,999,999 Wh
1 W
H
F20 R
04901-04904 359 6 20 obsolete-TOU Current Month Reg 1 VAhour (Quadrant 2) +9,999,999,999,999,999 VAh / 0 VAh
1 VA
H
F20 R
04905-04908 359 7 20 obsolete-TOU Current Month Reg 1 VARhour (Quadrant 2) +9,999,999,999,999,999 VARh / 0 VARh
1 VAR
H
F20 R
04909-04912 359 8 20 obsolete-TOU Current Month Reg 1 VAhour (Quadrant 3) +9,999,999,999,999,999 VAh / 0 VAh
1 VA
H
F20 R
04913-04916 359 9 20 obsolete-TOU Current Month Reg 1 VARhour (Quadrant 3) 0 VARh / -9,999,999,999,999,999 VARh
1 VAR
H
F20 R
04917-04918 360 0 30 TOU Current Month Reg 1 Peak Demand Watt (Quadrant 1 + 4) +32767 Watt / 0 Watt 1/ 65536 W sec F7 R
Time of Use Active Total Block
Time of Use Current Month Reg 1 Block