GE EPM 9650/9800 Computer Monitor User Manual


 
Address Line Pt
DNP
Ob
j
Description Range Units Type R/W
07840-07843 595 0 50 Maximum Total Average Power Factor Q14 Timestamp 12/31/9999 23:59:59.99 F3 R
07844-07847 595 1 50 Maximum Total Average Power Factor Q23 Timestamp 12/31/9999 23:59:59.99 F3 R
07848-07851 596 0 50 Minimum Total Average Power Factor Q14 Timestamp 12/31/9999 23:59:59.99 F3 R
07852-07855 596 1 50 Minimum Total Average Power Factor Q23 Timestamp 12/31/9999 23:59:59.99 F3 R
07856-07859 597 0 50 Total Average Power Factor Reset Timestamp 12/31/9999 23:59:59.99 F3 R
07860-07863 598 0 50 Reset Active TOU Time Stamp 12/31/9999 23:59:59.99 F3 R
08193-08320 Scratchpad Registers
08449-08512 Master Device Data, Port 4 (I/O) 12/31/9999 23:59:59.99 10 msec F3 R
08513-08576 Master Device Data, Port 3 9999 1 year F21 R
08577-08640 Master Device Data, Port 2 12/31/9999 23:59:59.99 10 msec F3 R
08641-08704 Master Device Data, Port 1 (232/485) 9999 1 year F21 R
12289-14336 Customized Modbus Readings R
16385-24576 Undefined R
24577-32768 Undefined R
34817-34820 TOU Calendar Year 1 Modification Time Stamp 12/31/9999 23:59:59.99 10 msec F3 R
34821 TOU Calendar Year 1 Calendar Year 9999 1 year F21 R
34822-34825 TOU Calendar Year 2 Modification Time Stamp 12/31/9999 23:59:59.99 10 msec F3 R
34826 TOU Calendar Year 2 Calendar Year 9999 1 year F21 R
34827-34830 TOU Calendar Year 3 Modification Time Stamp 12/31/9999 23:59:59.99 10 msec F3 R
34831 TOU Calendar Year 3 Calendar Year 9999 1 year F21 R
34832-34835 TOU Calendar Year 4 Modification Time Stamp 12/31/9999 23:59:59.99 10 msec F3 R
34836 TOU Calendar Year 4 Calendar Year 9999 1 year F21 R
34837-34840 TOU Calendar Year 5 Modification Time Stamp 12/31/9999 23:59:59.99 10 msec F3 R
34841 TOU Calendar Year 5 Calendar Year 9999 1 year F21 R
34842-34845 TOU Calendar Year 6 Modification Time Stamp 12/31/9999 23:59:59.99 10 msec F3 R
34846 TOU Calendar Year 6 Calendar Year 9999 1 year F21 R
Scratchpad Block
Time of Use Calendar Header Block
Customized Modbus Block
Enhanced Factory Settings Block
Enhanced Programmable Settings Block
Reset Active TOU Time Stamp
Master Device Data Blocks
2- 106