GE EPM 9650/9800 Computer Monitor User Manual


 
Address Line Pt
DNP
Ob
j
Description Range Units Type R/W
02591-02594 209 0 50 Phase Angle Block Time Stamp 12/31/9999 23:59:59.99 10 msec F3 R
02595 210 0 30 Phase Angle Phase A-N Voltage +180 degree / -180 degree 0.01 degree F9 R
02596 210 1 30 Phase Angle Phase B-N Voltage +180 degree / -180 degree 0.01 degree F9 R
02597 210 2 30 Phase Angle Phase C-N Voltage +180 degree / -180 degree 0.01 degree F9 R
02598 211 0 30 Phase Angle Phase A Current +180 degree / -180 degree 0.01 degree F9 R
02599 211 1 30 Phase Angle Phase B Current +180 degree / -180 degree 0.01 degree F9 R
02600 211 2 30 Phase Angle Phase C Current +180 degree / -180 degree 0.01 degree F9 R
02601 212 0 30 Phase Angle Phase A-B Voltage +180 degree / -180 degree 0.01 degree F9 R
02602 212 1 30 Phase Angle Phase B-C Voltage +180 degree / -180 degree 0.01 degree F9 R
02603 212 2 30 Phase Angle Phase C-A Voltage +180 degree / -180 degree 0.01 degree F9 R
02604 213 0 30 Voltage Phase Sequence F13 R
02605-02608 214 0 50 Block Window Average Block Time Stamp 12/31/9999 23:59:59.99 10 msec F3 R
02609 215 0 30 Block Window Average Status F14 R
02610-02611 216 0 30 Block Window Average VA +32767 VA / 0 VA 1/ 65536 VA sec F7 R
02612-02613 216 1 30 Block Window Average VAR +32767 VAR / -32768 VAR 1/ 65536 VAR sec F7 R
02614-02615 216 2 30 Block Window Average Watt +32767 W / -32768 W 1/ 65536 W sec F7 R
02616-02617 217 0 30 Maximum Block Window Average VA +32767 VA / 0 VA 1/ 65536 VA sec F7 R
02618-02619 217 1 30 Maximum Block Window Average Positive VAR +32767 VAR / 0 VAR 1/ 65536 VAR sec F7 R
02620-02621 217 2 30 Maximum Block Window Average Negative VAR 0 VAR / -32768 VAR 1/ 65536 VAR sec F7 R
02622-02623 217 3 30 Maximum Block Window Average Positive Watt +32767 W /0 W 1/ 65536 W sec F7 R
02624-02625 217 4 30 Maximum Block Window Average Negative Watt 0 W / -32768 W 1/ 65536 W sec F7 R
02626-02627 218 0 30 Minimum Block Window Average VA +32767 VA / 0 VA 1/ 65536 VA sec F7 R
02628-02629 218 1 30 Minimum Block Window Average Positive VAR +32767 VAR / 0 VAR 1/ 65536 VAR sec F7 R
02630-02631 218 2 30 Minimum Block Window Average Negative VAR 0 VAR / -32768 VAR 1/ 65536 VAR sec F7 R
02632-02633 218 3 30 Minimum Block Window Average Positive Watt +32767 W /0 W 1/ 65536 W sec F7 R
02634-02635 218 4 30 Minimum Block Window Average Negative Watt 0 W / -32768 W 1/ 65536 W sec F7 R
02636-02637 219 0 30 Coincident Block Window Average VAR for Maximum Positive Watt +32767 VAR / -32768 VAR 1/ 65536 VAR sec F7 R
02638-02639 219 1 30 Coincident Block Window Average VAR for Maximum Negative Watt +32767 VAR / -32768 VAR 1/ 65536 VAR sec F7 R
02640-02641 219 2 30 Coincident Block Window Average VAR for Minimum Positive Watt +32767 VAR / -32768 VAR 1/ 65536 VAR sec F7 R
02642-02643 219 3 30 Coincident Block Window Average VAR for Minimum Negative Watt +32767 VAR / -32768 VAR 1/ 65536 VAR sec F7 R
02644-02647 220 0 50 Maximum Block Window Average VA Time Stamp 12/31/9999 23:59:59.99 10 msec F3 R
Block Window Average Block
Phase Angle Block
2- 60