HP (Hewlett-Packard) 6600 Switch User Manual


 
Redundancy (Switches 8200zl)
Displaying Management Information
Show Flash
The show flash command displays which software version is in each flash
image. The Default Boot field displays which flash image will be used for the
next boot.
ProCurve(config)# show flash
Will boot from primary flash
Image Size(Bytes) Date Version Build #
----- ---------- -------- ------- -------
Primary Image : 7463821 03/05/07 K.12.XX 351
Secondary Image : 7463821 03/05/07 K.12.XX 351
Boot Rom Version: K.12.01
Default Boot : Primary
on the next boot.
Figure 15-15. Example of Show Flash Command
Show Version
The show version command displays system software image information for
both management modules as well as which module is the active management
module and which is the standby management module. The Boot Image field
displays which flash image last booted from, even if the boot set-default
command has been set to change the flash booted from on the next boot. The
output of the show version command when redundancy is enabled is shown in
Figure 15-16.
ProCurve(config)# show version
Management Module 1: Standby
Image stamp: /sw/code/build/btm(t2g)
Mar 5 2007 13:20:59
K.12.XX
351
Boot Image: Primary
Management Module 2: Active
Both management
modules were booted
Image stamp: /sw/code/build/btm(t2g)
Mar 5 2007 13:20:59
from primary flash.
K.12.XX
351
Boot Image: Primary
Figure 15-16. Example of Show Version Command when Redundancy is Enabled
When redundancy is disabled, the output of the show version command
changes, as shown in Figure 15-17.
15-25