HP (Hewlett-Packard) 6600 Switch User Manual


 
File Transfers
Copying Diagnostic Data to a Remote Host, USB Device, PC or UNIX Workstation
slot-id: retrieves the crash data from the module in the
specified slot.
mm: retrieves the crash data from both management modules
and concatenates them.
oobm: For switches that have a separate out-of-band
management port, specifies that the transfer will be through
the out-of-band management interface. (Default is transfer
through the data interface.)
Copying Crash Log Data Content to a Destination Device
Syntax: copy crash-log [<slot-id | mm>] tftp <ip-address>
<filepath and filename> [oobm]
copy crash-log [<slot-id | mm>] usb <filename>
copy crash-log [<slot-id | mm>] xmodem
where: slot-id = a - h, and retrieves the crash log from
the processor on the module in the specified slot.
mm Retrieves the crash log from the switch’s
chassis processor. When mm is specified,
crash files from both management modules are
copied.
oobm For switches that have a separate out-of-band
management port, specifies that the transfer
will be through the out-of-band management
interface. (Default is transfer through the data
interface.)
These commands copy the Crash Log content to a remote host,
attached USB device, or to a serially connected PC or UNIX
workstation. You can copy individual slot information or the
management module (mm) switch information. If you do not
specify either, the command defaults to the mm data.
For example, to copy the Crash Log for slot C to a file in a PC connected to
the switch: