HP (Hewlett-Packard) RP4440 Server User Manual


 
Installing the System
Troubleshooting
Chapter 3
142
Memory
bank X (0-7)
DIMM xA DIMM xB DIMM xC DIMM xD The specified DIMM has failed—reseat or
replace the memory board and DIMM.
If all the LEDs for a rank (0-7) are lit and the
memory config error LED is lit, then the
DIMMs in the specified rank are
mismatched—review the information on
installing memory.
Check power
supply
n/a n/a n/a The faulty power supply LED (located on
Power supply) is lit. Reseat the power supply.
Memory
config error
n/a n/a n/a The DIMMs in a rank are
mismatched—review the information on
installing memory.
Processor
config error
n/a n/a n/a The processors are mismatched—review the
information on installing processors.
Missing
component
n/a n/a n/a A required component(s) is not detected.
Check that recently installed items are
correctly installed.
System temp n/a n/a n/a Make sure nothing is blocking server airflow.
Check that recently installed items are
correctly installed.
Check event
log
n/a n/a n/a An event has occurred that requires
attention.
Table 3-22 QuickFind Diagnostic Panel LED Definitions (Continued)
Item LED 0 LED1 LED2 LED3 Details