HP (Hewlett-Packard) RP4440 Server User Manual


 
Chapter 6
Removing and Replacing Components
Removing and Replacing PCI/PCI-X Cards
220
OLA
Before installing a PCI/PCI-X card, ensure that the proper drivers for that PCI/PCI-X card are installed.
NOTE If you are installing the Graphics Kit A6150B, use slots 3-8. However, do not install the
included USB card. The server currently supports USB and the ports are already located on the
rear of the server.
If you are installing the RAID card A7143A, you must install it into slot 8. If you install this
card in any other slot, it interferes with the manual retention latch (MRL) on the OLX divider
in the next slot. Because of this interference, you can install only two RAID cards in the system
in slot 1 and slot 8.
To add a PCI/PCI-X card into an empty slot, follow these steps:
Step 1. If rack-mounted, slide the server out from the rack until it stops. (See “Accessing a Rack-Mounted
Server” on page 177.)
Step 2. Remove the top cover from the chassis. (See “Removing the Top Cover” on page 182.)
Step 3. Select an empty slot and pull up on the MRL located on the OLX divider approximately 75 degrees.
PCI Slot 2 - GigaBit LAN Port B 0/1/2/1 0/1/2/1 0x20-0x3F
PCI Slot 3 0/4/1 0/4/1 0x80-0x9F
PCI Slot 4 0/4/2 0/4/2 0x80-0x9F
PCI Slot 5 0/5/1 0/5/1 0xA0-0xBF
PCI Slot 6 0/5/2 0/5/2 0xA0-0xBF
PCI Slot 7 0/2/1 0/2/1 0x40-0x7F
PCI Slot 8 0/6/1 0/6/1 0xC0-0xFF
UPS Communications Controller 0/0/1/0 0/0/1/0 0x00-0x1F
Local/Remote Serial Controller 0/0/1/1 0/0/1/1 0x00-0x1F
Table 6-6 PCI I/O Hardware Paths (Continued)
PCI Card Functionality
Mapper
Path
HP-UX
Path
PCI Bus
Address