225
Safety data sheet Océ TDS400 printer
The content of this safety data sheet is subject to the disclaimer of liability on page 224 of this manual.
PRODUCT SAFETYDATA SHEET
Océ-USA, Inc.
Number
E-717-a-US
Date
August 2000
Copyright © 2000 Océ-Technologies B.V., Venlo, NL
Model Océ TDS400 printer
Description
Electrophotographic printer, instant printing, console model, plain paper, organic
photoconductive drum, powder toner
Max. process speed
3 m/min
Dimensions
Width
Engine Controller
1roll 2roll
1352 mm 1352 mm 206 mm
Depth
899 mm 899 mm 437 mm
Height
1251 mm 1251 mm 444 mm
Weight
175kg 185kg 15kg
Vol tag e
100/115/230 V 100/115/230 V 100/230 V
Frequency
50/60 Hz 50/60 Hz 50-60 Hz
Current-rated
15/15/7,5 A 15/15/7,5 A 0,9 A
Current-max
20/20/10 A 20/20/20/10 A 6/3 A
Power consumption, stand by
30 W
Power consumption, operation
1,5 kW 4 0 W
EPA
E
NERGY
S
TA R
®
* Power consumption
sleep mode
42 W (total system)
Mains connection
Cable with plug
Safety class
I (IEC 536) Protective earth connection
Protection class
IP 20 (IEC 529)
Sound pressure level
(at bystander position)
Standby In operation
24 dB(A) main body 54 dB(A)
impulse L
i
= 4 dB(A)
Sound power level
40 dB(A) main body 62 dB(A)
Radio interference
Complies with Directive 89/336/EEC and FCC rules and regulations, part 15 Class A.
Radiation
Below the Threshold Limit Values for UV, Visible and IR radiation (TLV list of ACGIH).
Heat emission
Standby 70 W; at continuous operation 1,5 kW
Ozone emission
0,04 mg/min at continuous operation
Room volume
Recommendation: min. 25 m
3
Room ventilation
Recommendation: min. 12,5 m
3
/h (natural ventilation)
Use simulation at random
operation
With a room volume and ventilation as recommended and a daily volume of 150 m (much
more than average) the use simulation at random operation gives the following ozone
concentrations:
- Time weighted average 0,01 mg/m
3
(0,005 ppm)
- Peak 0,002 mg/m
3
(0,001 ppm)
Threshold Limit Value/Occupational Exposure Limit
(Time Weighted Average) for ozone 0,2 mg/m
3
(0,1 ppm)
Odour Perception Limit for ozone 0,04 mg/m
3
(0,02 ppm)
Consumables
Océ OPC Drum (Océ Safety Data Sheet E-218)
Océ B5 Toner (Océ Safety Data Sheet E-199)
Océ D5 Developer (Océ Safety Data Sheet E-200)
Océ Copying Materials.
This apparatus is suitable for processing recycling paper which complies with the
requirements of ENV 12281.
Additional safety information
The ozone filter does not have to be replaced to keep the ozone concentration in the
workplace below 0,04 mg/m
3
(i.e. the life of the filter equals that of the apparatus).
Listed according to standard UL 1950 and CAN/CSA-C22.2 No.950 EPA
E
NERGY
S
TA R
®
LISTED 927F
INFORMATION
TECHNOLOGY
EQUIPMENT
E 69871