132
cifically, this bus connects the FPC and BMC. Also, there may be an SMM based device on the
bus and a cluster card connector based device.
On the FPC, this bus consists of the I2C_BACKUP_SCL and the I2C_BACKUP_SDA signals.
10.2.12.3 I
2
C Development Support Jumpers
Development support jumpers on the I
2
C buses are provided to isolate I
2
C devices. These jump-
ers must first be enabled by removing Resistor Pack RP3A4 and RP3A5 and adding all J3 jump-
ers. Once enabled, specific I
2
C devices/sections can be isolated by removing the jumpers.
In production, the jumper blocks are not stuffed.
10.2.13 Miscellaneous
10.2.13.1 Signal RESET_OUTPUTS_L
The RESET_OUTPUTS_L signal is used to enable the output latch. Immediately after the micro-
controller comes out of a hard reset, this signal goes to the deasserted (high) state. In this state,
the output latch is output disabled, but retains any states written to it. The microcontroller initial-
izes the latch with proper values before the RESET_OUTPUTS_L signal is asserted (low).