67
5.7 Fan Speed Control
The fan circuitry implements variable speed fan control and fan failure detection.
5.8 Environmental Requirements
5.8.1 Physical Environment
The power supply is located inside an Intel
®
system assembly. A system may contain two or
three power supplies.
5.8.2 Thermal Protection
The power supply incorporates thermal protection that causes a shutdown if air flow through the
power supply is insufficient. Thermal protection activates a shutdown if the temperature of any
power supply component is more than 85% (°C) of rated temperature. This shutdown takes place
prior to over-temperature induced damage to the power supply.
5.9 Regulatory Agency Requirements
The power supply must have UL recognition, CSA certification to level 3, Bauart and any NOR-
DIC CENELEC certified (such as SEMKO, NEMKO or SETI) markings demonstrating compli-
ance. The power supply must also meet FCC Class B, VDE 0871 Level B, and CISPR Class B
requirements.
Table 5-15: Power Supply LEDs and Output Signal State Logic
Power Supply LEDs Power Supply Output Signal States Input to
PS
Conditions
PWR
(green)
PRFL
(yellow)
FAIL
(yellow)
P_Good
H = pwr
good
Pred. Failure
H = pred.
failure
PS Failure
H = PS OK
PS On
H = PS
enable
No AC Power OFF OFF OFF L L L L
AC In/Standby On Blinking OFF OFF L L H L
DC Outputs OK ON OFF OFF H L H H
Power Supply
Failure
OFF OFF ON L L L H
Current Limit ON OFF Blinking/
No Latch
LL H H
Predictive Failure ON Blinking/
Latched
OFF H H H H