Intel OCPRF100 MP Server User Manual


 
OCPRF100 MP Server System Technical Product Specification
Revision 1.0
37
3.6 Specifications
3.6.1 Environmental Specifications
The system will be tested to the environmental specifications as indicated in Table 3-8.
3.6.2 Physical Specifications
Table 3-8 describes the physical specifications of the system.
Table 3-8: Environmental Specifications Summary
Environmental Feature Specification
Operating temperature 10° to 35°C (50° to 95°F). See Altitude exception.
Nonoperating temperature -40°C to 70°C (-40°F to 158°F).
Altitude 0 to 3048 m (0 to 10000 ft.). Note: Maximum ambient temperature is
linearly derated between 1520 m (5000 ft.) and 3050 m (10000 ft.)
by 1°C per 305 m (1000 ft.).
Operating humidity 85%, noncondensing at 40°C (104°F).
<33°C (91.4°F) wet bulb at 40°C (104°F) without peripherals.
Nonoperating humidity 95%, noncondensing at +55°C (131°F).
Safety UL 1950, CSA 950, IEC 950, TUV EN60 950, NEMKO.
Emissions Certified to FCC Class B; tested to CISPR 22B,
EN 55022, and registered with VCCI.
Immunity Verified to comply with EN 50082-2.
Electrostatic discharge (ESD) Tested to ESD levels up to 20 kilovolts (kV) air discharge without
physical damage as per the Intel
®
environmental test specification.
Acoustic Sound pressure: < 57 dbA at ambient temperatures.
< 28°C measured at bystander positions in operating mode.
Sound power: < 6.5 BA at ambient temperatures.
< 28°C in operating mode.