CAUTION:
When replacing the lithium battery, use only Part Number 33F8354 or an
equivalent type battery recommended by the manufacturer. If your system has
a module containing a lithium battery, replace it only with the same module
type made by the same manufacturer. The battery contains lithium and can
explode if not properly used, handled, or disposed of.
Do not:
v Throw or immerse into water
v Heat to more than 100° C (212° F)
v Repair or disassemble
To install the replacement battery, do the following:
1. Follow any special handling and installation instructions that come with the
replacement battery.
2. Insert the replacement battery 1:
a. Hold the battery in a vertical orientation so that the smaller side is facing the
socket.
b. Place the battery into its socket, and press the battery towards the socket
until it clicks into place. Make sure that the battery clip holds the battery
securely.
3. Install and lock the left-side cover (see “Installing the side cover” on page 33).
4. Reconnect the external cables and power cords; then, turn on the attached
devices and turn on the server.
Note: You must wait approximately 2 1/2 minutes after you connect the server
power cord to an electrical outlet before the power-control button becomes
active.
5. Start the Setup Utility and reset the configuration:
v Set the system date and time.
v Set the power-on password.
v Reconfigure the server.
See “Starting the Setup Utility” on page 110 for details.
Removing and replacing FRUs
Field replaceable units (FRUs) must be installed only by trained service technicians.
90 ThinkServer TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530: Installation and User Guide