Lenovo 6528 Server User Manual


 
Installing a non-hot-swap power supply
This procedure applies only to server models that have a non-hot-swap power
supply. See “Removing the hot-swap power supply cage” on page 87 for
information about the installation of a hot-swap power supply.
To install a non-hot-swap power supply, complete the following steps:
1. Position the power supply in the chassis so that the screw holes in the power
supply are aligned with the corresponding holes in the rear of the chassis.
2. Install the four screws that secure the power supply to the chassis.
3. Connect the cables from the power supply to the system board and all internal
components (see “System-board internal connectors” on page 19 for the
locations of the internal connectors).
4. Install the side cover (see “Installing the side cover” on page 33).
5. Lock the side cover if you unlocked it during removal.
6. Reconnect the external cables and power cords; then, turn on the attached
devices and turn on the server.
98 ThinkServer TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530: Installation and User Guide