7-24 Chapter 7: Programming
extension. The default is 2- and 5-digit extensions and scanning a valid
Hex tag causes the program to go to the next parameter option.
Send Data
The Send Data parameter has three selections: Data As Decoded,
Periodical Code Data Only, and CF Hex If Periodical Data Not
Decoded. If you scan the Hex 0 tag, the data is sent as decoded,
whether or not there are extension digits. If you scan the Hex 1 tag,
only valid periodical codes are sent. If you scan the Hex 2 tag, a
hexadecimal CF is sent as the extension if the scanner/scale could not
read a 2- or 5-digit code. The default is Data as Decoded. Scanning a
valid Hex tag causes the program to go to the Base Programming State.
Program Example
In this example the UPC/EAN bar codes are programmed to have:
•
UPC/EAN – enabled
•
Version D tags – not read
•
Extend UPC-A to EAN-13 – disabled
•
Extend UPC-E to UPC-A – disabled
•
Periodical Codes – enabled
•
Periodical Code Extensions – 2- and 5-digit extensions
•
Send data data – as decoded
Your Program
0
Version
D
B
0
Extend
UPC-A
C
0
Extend
UPC-E
D
1
Periodical
Codes
E
2
Periodical
Code
Extension
0
Send
Data
Bar Codes - 1
1 3
1
UPC/EAN
A
B055