NCR 7870 Scanner User Manual


 
xviii User's Guide
Following is the radiant energy of the laser light as applied to each of
the specified requirements.
Maximum Average Radiant Power (CDRH Calculation)
0.87 microwatts
Accessible Emission Limit (CDRH Calculation)
3.9 microwatts
Maximum Radiant Power (EN60825-1 / IEC 825-1 Calculation)
0.45 milliwatts
Accessible Emission Limit (EN60825-1 / IEC 825-1 Calculation)
0.59 milliwatts
Caution: Use of controls or adjustments or performance of procedures
other than specified herein may result in hazardous radiation
exposure.