NCR 7870 Scanner User Manual


 
5-6 Chapter 5: Calibration
4.
Remove the Scale Board Shield.
a)
Break seal wire and seal sticker if present.
b)
Remove thumbscrew. Use needle-nosed pliers to loosen if
thumbscrew is tight.
c)
Remove Shield.
Scale Hinge Assembly
Calibration Switch (under shield)
Scale Board Shield
11040
5.
Set Top Plate on rubber bumpers of Scale Hinge Assembly. Make
sure bumpers fit into corresponding sockets on bottom of Top
Plate.
6.
Apply power to 7870.
7.
Does the unit have any of the following: an Integrated Display, a
7825 Remote Display, or the Voice Messaging Feature (must be
enabled)?
NO
Go to Section 3 -
Connecting the Field Service Calibration
Display
YES
Go to Section 4
Performing the Calibration