3-18 Chapter 3: Site Preparation
Checkstand Hole
When cutting the checkstand hole, also called a cutout, take care to
maintain the specified dimensions. While this is essential for all
models, it is critical for units with a scale.
•
For all models, the leading edge of the Top Plate must be flush or
no more than 15 cm (0.06 in.) below the top of the checkstand. The
trailing edge of the Top Plate must be flush with the top of the
checkstand.
•
For proper scale operation, the clearance between leading and
trailing edges of the Top Plate and the checkstand must be
maintained.
•
For European installations, a 5.1 cm (2 in.) border must be provided
around the leading edge, trailing edge, and operator side of the
scanner scale. This border must contain the words “NO WEIGH
AREA.”
99999
An NCR 7870-1000 may be placed in an existing cutout for an NCR
7820 and an NCR 7870-2000 may go into a cutout for the NCR 7824.
Before utilizing an existing cutout, you MUST ensure that the cutout
has the correct dimensions before installing the 7870.