Nortel Networks 450 Switch User Manual


 
Using the BayStack 450 10/100/1000 Series Switch
1-78
302401-D Rev 00
In the configuration example shown in Figure 1-50, the designated monitor port
(port 23) can be set to monitor traffic in any of the following modes:
Monitor all traffic received by port X.
Monitor all traffic transmitted by port X.
Monitor all traffic received and transmitted by port X.
Monitor all traffic received by port X or transmitted by port Y.
Monitor all traffic received by port X (destined to port Y) and then transmitted
by port Y.
Monitor all traffic received/transmitted by port X and received/transmitted by
port Y (conversations between port X and port Y).
As shown in the Port Mirroring Configuration screen example (Figure 1-51
),
port 23 is designated as the Monitor Port for ports 24 and 25 in switch S1.
The Monitoring Mode field [ - > Port X or Port Y - > ] indicates that all traffic
received by port X or all traffic transmitted by port Y is currently being monitored
by the StackProbe attached to Monitor Port 23.
The screen data displayed at the bottom of the screen shows the currently active
port mirroring configuration.
Note: The Unit value (in the Unit/Port field) is not configurable when the
switch is operating standalone. For detailed information about the MultiLink
Trunk Configuration screen fields, see “MultiLink Trunk Configuration” on
page 3-37.
kombk.book Page 78 Tuesday, June 29, 1999 3:25 PM