Installing the BayStack 450 Switch
302401-D Rev 00
2-3
Installation Procedure
This section provides the requirements and instructions for installing the
BayStack 450 switch on a flat surface or in a standard 19-inch utility rack. If you
install the switch in a rack, ground the rack to the same grounding electrode used
by the power service in the area. The ground path must be permanent and must not
exceed 1 ohm of resistance from the rack to the grounding electrode.
Installing the BayStack 450 Switch on a Flat Surface
Note:
An optional wall mount kit is available for the BayStack 450 switch
(Order Number Al2018003). See your Nortel Networks sales representative
for ordering information. Installation instructions are provided with the wall
mount kit.
Caution:
When this device is installed in a stack on a shelf or tabletop, the
accumulated weight of the port cables increases with the height of the shelf or
tabletop.
Achtung:
Wenn dieses Gerät in einem Stapel auf einem Tisch oder einem
Regalboden installiert wird, erhöht sich das Gesamtgewicht der
Schnittstellenkabel mit der Höhe des Regalbodens oder Tisches.
Attention:
Si l'appareil est posé dans un rack ou sur une étagère, notez bien
que le poids du câblage réseau augmente avec la hauteur de l'installation.
Precaución:
Cuando este dispositivo se instala apilado en un estante o sobre
una mesa, el peso acumulado de los cables de los puertos aumenta según la
altura del estante o de la mesa.
Attenzione:
Quando il dispositivo viene installato in stack su un ripiano o su
un tavolo, il peso dei cavi connessi alle porte aumenta in proporzione
all'altezza del ripiano o del tavolo.
kombk.book Page 3 Tuesday, June 29, 1999 3:25 PM