Table 3-23 describes the Renumber Stack Units screen options:
Table 3-23. Renumber Stack Units Screen Options
Option Description
Current Unit Number
Read-only fields listing the current unit number of each of the configured stack
units. The entries in this column are displayed in order of their current physical
cabling with respect to the base unit, and can show nonconsecutive unit numbering
if one or more units were previously moved or modified. The entries can also
include unit numbers of units that are no longer participating in the stack (not
currently active).
MAC Address
Read-only field listing the MAC address of the corresponding unit listed in the
Current Unit Number field.
New Unit Number
User-settable field showing the current unit number of each unit in the stack. You
can change any of the fields, as required. You can also delete entries by typing
zero (0) or using the space bar to clear the field.
Default Value Current stack order
Range 1 to 8
Renumber units with
new setting?
Specifies whether to start the renumbering process (default is No). Use the
spacebar to toggle the selection to Yes.
Renumbering resets the switch with the current configuration values. When you
select this option, the switch resets, runs a self-test, then displays the Nortel
Networks logo screen. After you press [Ctrl]-Y at the screen prompt, the console
screen temporarily displays the (standalone) BayStack 450 main menu. Then,
within 20 seconds, the console screen refreshes and displays the main menu
screen for the stack configuration. The Unit LEDs display the new numbering order.
Default Value No
Range No, Yes