Omron C200HE Computer Hardware User Manual


 
8
Function CapabilityFunction
C200HSC200HX/HG/HE
CPU Unit
functions
RS-232C port Available in the
C200HX/HG/HE-CPU4j-E/6j-E
Available in the
C200HS-CPU2j-E
/3j-E
Clock function Available in all except the C200HE-CPU11-E Available in all models
SYSMAC NET Link and
SYSMAC LINK functions
Communications Boards can be installed in
all PCs except the C200HE-CPU11-E.
(Board model numbers:
C200HW-COM01/04-E)
Available in the
C200HS-CPU3j-E
Communications
Boards
--- Communications Boards can be installed in
all PCs except the C200HE-CPU11-E. These
Boards can provide the following functions:
SYSMAC NET Link and SYSMAC LINK,
Communications Ports (Ports 1 and 2), and
Protocol Macro functions
---
Special I/O Units --- The IORD(––) and IOWR(––) instructions
allow data to be transferred to and from
Special I/O Units.
---
Interrupts
Interrupt Input Units 2 Units (16 inputs) 1 Unit (8 inputs)
Communications Board
interrupts
Can be set. ---
Response characteristics Same as the C200HS, although a 1-ms
response is possible in the C200HW-SLKjj
Normal mode: 10 ms
High-speed mode: 1 ms
(Always 10 ms when a
SYSMAC NET Link or
SYSMAC LINK is used.)
PTs --- NT Link (1:1) or NT Link (1:N)
(Up to 8 PTs can be connected from the
RS-232C port through an RS-422/485 Link
Adapter. When the C200HE-CPUjj-E with
a Communications Board is used, only 3 PTs
can be connected)
NT Link (1:1)
SYSMAC LINK
Service time 3.5 ms max. (1 operating level) 10.8 ms max.
(1 operating level)
Remote programming Possible from the Peripheral Port or RS-232C
Ports (including Communications Boards).
Possible from the
Peripheral Port.
Effect on response time None 10 ms in any mode
1-8-2 Program Compatibility
C200HS programs and Memory Cassettes can be used as is in the C200HX/
HG/HE and programs developed for the C200H can be transferred for use in the
C200HX/HG/HE very easily.
Detailed procedures for the individual steps involved in transferring programs
can be found in the SSS Operation Manuals. You will also require a
CQM1-CIF02 Connecting Cable to connect the computer running SSS to the
C200HS.
Precautions Observe the following precautions when transferring C200H programs to the
C200HX/HG/HE.
If a C200H program including the SET SYSTEM instruction (SYS(49)) is trans-
ferred to the C200HX/HG/HE, the operating parameters set by this instruction
will be transferred to the C200HX/HG/HEs PC Setup area (DM 6600, DM
6601, and DM 6655) and overwrite any current settings. Be sure to confirm
that the settings in these words are correct before using the PC after program
transfer.
C200HX/HG/HE Features Section 1-8