9
• If the C200H program accesses the C200H’s error log in DM 0969 to DM 0999,
the addresses of the words being accessed must be changed to DM 6000 to
DM 6030, which is the error log area for the C200HX/HG/HE.
• Any programs that rely on the execution cycle time (i.e., on the time required to
execute any one part of all of the program) must be adjusted when used on the
C200HX/HG/HE, which provides a much faster cycle time.
Using Internal Memory The following procedure outlines the steps to transfer C200H programs to the
user memory inside the C200HX/HG/HE.
1, 2, 3... 1. Transfer the program and any other required data to the SSS work area.
This data can be transferred from a C200H CPU Unit, from floppy disk, or
from a C200HS Memory Unit.
To transfer from a C200H CPU Unit, set the PC for the SSS to the C200H,
connect the SSS to the C200H, go online, and transfer the program and any
other required data to the SSS work area. You will probably want to transfer
DM data and the I/O table, if you have created an I/O table for the C200H.
or To transfer from floppy disk, set the PC for the SSS to the C200H in the
offline mode and load the program and any other require data to the SSS
work area. You will probably want to load DM data and the I/O table, if you
have created an I/O table for the C200H.
or To transfer from a C200H-MP831, set the PC for the SSS to the C200H in the
offline mode and read data from the Memory Unit into the SSS work area.
2. Go offline if the SSS is not already offline.
3. Change the PC setting for the SSS to the C200HX/HG/HE.
4. If you want to transfer I/O comments together with the program to the
C200HX/HG/HE, allocate UM area for I/O comments.
5. Connect the SSS to the C200HX/HG/HE and go online.
6. Make sure that pin 1 on the C200HX/HG/HE’s CPU Unit is OFF to enable
writing to the UM area.
7. Transfer the program and and any other required data to the C200HX/HG/
HE. You will probably want to transfer DM data and the I/O table, if you have
created an I/O table for the C200H.
8. Turn OFF the C200HX/HG/HE and then back ON to reset it.
9. Test program execution before attempting actual operation.
Using Memory Cassettes The following procedure outlines the steps to transfer C200H programs to the
C200HX/HG/HE via EEPROM or EPROM Memory Cassettes. This will allow
you to read the program data from the Memory Cassette automatically at
C200HX/HG/HE startup. The first four steps of this procedure is the same as
those used for transferring directly to the C200HX/HG/HE’s internal memory
(UM area).
1, 2, 3... 1. Transfer the program and any other required data to the SSS work area.
This data can be transferred from a C200H CPU Unit, from floppy disk, or
from a Memory Unit.
To transfer from a C200H CPU Unit, set the PC for the SSS to the C200H,
connect the SSS to the C200H, go online, and transfer the program and any
other required data to the SSS work area. You will probably want to transfer
DM data and the I/O table, if you have created an I/O table for the C200H.
or To transfer from floppy disk, set the PC for the SSS to the C200H in the
offline mode and load the program and any other required data to the SSS
work area. You will probably want to load DM data and the I/O table, if you
have created an I/O table for the C200H.
or To transfer from a C200H-MP831, set the PC for the SSS to the C200H in the
offline mode and read data from the Memory Unit into the SSS work area.
C200HX/HG/HE Features Section 1-8