Printronix Network Interface Card Network Card User Manual


 
Store Commands
313
store pping packet <number of packets>
Example:
store pping packet 1
Store the value of the packet. It is the number of ICMP Echo
Request packets that will be sent by the periodic ping client on
each period.
Default: 1
store pping period <minutes>
Example:
store pping period 5
Store the value of the period. <minutes> is the amount of time
from 1 to 5 minutes defines the periodic ping sequence will be
repeated.
Default: 5
store pping from default
Example:
store pping from default
Store all the periodic ping default settings to flash memory so
taht they are retained after power up.
store pserver name
Example:
store pserver name NIC1234
Command to change the print server name.
store pserver opts [[-]jobsecurity]
[jobtimeout <seconds>] [jobcontrol[off|standard|
enhanced]]
Example:
store pserver opts [-]jobcontrol
If jobcontrol is disabled then the need for start of job / end of
job flow control with the printer is determined by the printer. Job
flow control is used for jobs requiring backchannel responses
such as IPDS, TN5250 and PJL jobs only. This is available as
a performance enhancement for LPR, TCP socket printing etc.
The job flow control has no affect on IPDS, TN5250, and PJL
jobs. These options perform their own control. When jobcontrol
is enabled all jobs will be supported with job flow control.
NOTE: When jobcontrol is disabled, dynamic config loading on a
model change is also disabled.