Printronix Series 5 Printer User Manual


 
Configuration Menus 4–69
P–Series XQ Emulation
Control Code 06
Control Code 06 defines the function of ASCII code 06 hex (ACK). You can select
an alternate line spacing of 6, 8 or 10.3 LPI.
Define CR Code
This option controls the action of the printer when it receives a Carriage Return
code (0D hex) from the host computer. If this feature is enabled, each time the
printer receives a Carriage Return, it inserts an additional Line Feed code (0A
hex) into the data stream. Do not use this feature if the host computer sends Line
Feeds to the printer.
CR = CR does not insert an extra Line Feed after each Carriage Return.
CR = CR + LF inserts an extra Line Feed after each Carriage Return.
The next print position will be print position 1 of the next line.
Auto LF
This option defines the printer actions when print data is received past the forms
width setting.
DISABLE discards any data past the forms width.
ENABLE performs an automatic carriage return and line feed when data
is received past the forms width.
Define LF Code
This option determines whether an automatic carriage return should occur
whenever a line feed command is received.
LF = LF does not perform an automatic carriage return. The next print
position will be the current print position of the next line.
LF = CR + LF forces an automatic carriage return with each line feed
command. The next print position is position 1 of the next line.