Printronix ThermaLine Series Printer User Manual


 
4–81Commands
PCX Logo
Purpose Places the IGP/PGL in the Create Logo mode, where logos can be defined
using the PCX file format.
Mode NORMAL
Format (cc)(LOGO;logoname;PCX[;DISK](T)
<PCX raster data> (cc) RASTEREND [T]
END(T)
(cc) The Special Function Control Character.
LOGO The Logo command; enter LOGO.
logoname Enter a maximum of 12 alphanumeric characters for
the name of the logo. (Refer to page 4–5 for a list of
allowable Logo Name characters.) All future
references to this logo (Delete Logo or Logo Call
commands) must use this name. If a logo is defined
with the same name as a logo already existing in
memory, the newly defined logo will replace the
existing logo.
PCX The command denoting raster data in PCX format;
enter PCX.
DISK Optional parameter to store the logo in the IGP/PGL
external memory modules. Enter DISK.
T Line terminator.
PCX raster data Scanned data in PCX format; data must be black and
white. Grey scales or color PCX files are currently not
supported. Both uncompressed and compressed
formats are supported.
(cc) The Special Function Control Character.
RASTEREND Denotes the end of the PCX raster data. Enter
RASTEREND.